输液泵和便携式医疗设备设计的重要注意事项
上传用户:soothmusic
上传日期:2012-06-14
文件类型:PDF
文件大小:100.30K
资料积分:0分 积分不够怎么办?
摘要:本教程讨论了需要注意的设计时,输液泵,包括FDA的监管,自我测试电路,并符合IEC 60601-1医用电气设备标准的关键考虑因素。它还提供摘要泵机制的覆盖面,上电自检( POST ) ,低功耗和便携性,报时,报警器,静电放电变量设计。
Maxim > App Notes > A/D and D/A Conversion/Sampling Circuits Amplifier and Comparator Circuits Battery Management
Display Drivers Sensors
Keywords: infusion pump, portable medical, medical equipment, IEC 60601-1 May 10, 2010
APPLICATION NOTE 4677
Important Considerations for Infusion Pump and Portable Medical
Designs
Abstract:This tutorial discusses critical considerations requiring attention when designing an infusion pump, including FDA
regulation, self-test circuitry, and meeting the IEC 60601-1 standard for electrical medical equipment. It also provides summary
coverage of pump mechanisms, power-on self-test (POST), designing for low power and portability, timekeeping, alarms, and
electrostatic-discharge variables.
Overview
Comput
Maxim > App Notes > A/D and D/A Conversion/Sampling Circuits Amplifier and Comparator Circuits Battery Management
Display Drivers Sensors
Keywords: infusion pump, portable medical, medical equipment, IEC 60601-1 May 10, 2010
APPLICATION NOTE 4677
Important Considerations for Infusion Pump and Portable Medical
Designs
Abstract:This tutorial discusses critical considerations requiring attention when designing an infusion pump, including FDA
regulation, self-test circuitry, and meeting the IEC 60601-1 standard for electrical medical equipment. It also provides summary
coverage of pump mechanisms, power-on self-test (POST), designing for low power and portability, timekeeping, alarms, and
electrostatic-discharge variables.